40+ 00735 Potentiometer In Positioning Motor For Air Recirculation Flap G143 Info
00735 potentiometer in positioning motor for air recirculation flap g143. 00727 030 Potentiometer in positioning motor for defroster flap -G135 Open circuitshort circuit to positive 00735 030 Potentiometer -G143 in the air recirculation flap control motor -V113 Open circuitshort circuit to positive. продавам нов диагностичен кабел vag-com 704Цена 90лвкабела е чисто нов не е ползвантел 0888011907 - Никола. 00735 - Potentiometer in Positioning Motor for Air recirculation Flap G143 30-10 - Open or Short to Plus - Intermittent At the time i just cleared them as the air was working fine and a member on here has had the same codes after a flat battery and not using the climate for a while. 00735 - Potentiometer in Positioning Motor for Air recirculation Flap G143 09-00 - Adaptation Limit Surpassed Interestingly could audiably hear the motors kind of groaning at each extent. 00604 - Potentiometer Positioning Motor for Air Flow Flap G113 30-10 - Open or Short to B - Intermittent 00716 - Air recirculation Flap Positioning Motor V113 41-10 - Blocked or No Voltage - Intermittent 00735 - Potentiometer in Positioning Motor for Air recirculation Flap G143 30-10 - Open or Short to B - Intermittent. 00819 - High Pressure Sensor G65. Right V159 41-00 - Blocked or No Voltage 00716 - Air recirculation Flap Positioning Motor V113 41-00 - Blocked or No Voltage 00735 - Potentiometer in Positioning Motor for Air recirculation Flap G143 09-00 - Adaptation Limit Surpassed 00819 - High Pressure Sensor G65 30-00 - Open or Short to Plus. 00735 Potentiometer on Positioning motor for air recirculation flap G143 30 -00 open or short to plus - intermittent 00818 Sensor for Evaporator outlet temperature G263 VCDS is comunicating with all the other modules but is randomly coming up with too many errors to continue when in HVAC module measuring blocks basic settings etc. The flap is jammed or the gears are rounded. Check flap if its stuck. I need the location of this potentiometer I believe its the V113 one I need I have been to the scrapyard today and tried all the one on the passenger side however the code comes straight back there are 3 more motors located on the drivers side Ive tried the bottom one and that didnt work so it must. 00735 - Potentiometer in Positioning Motor for Air recirculation Flap G143 29-10 - Short to Ground - Intermittent Ive tried exercising it with the temp and direction buttons and also using VCDS but doesnt seem to get any better - do I need to keep repeating the exercise or does this point to a more fundamental problem.
00716 - Air recirculation Flap Positioning Motor V113 41-10 - Blocked or No Voltage - Intermittent. Then found another option where each motor and function was stepped through after clearing the codes again and running through the stepped test i got the 2 faults as above again. 00735 - Potentiometer in Positioning Motor for Air recirculation Flap G143 30-10 - Open or Short to Plus - Intermittent. 01810 - Actuating Motor for Temperature Flap. 00735 potentiometer in positioning motor for air recirculation flap g143 VCDS gives me the fault code 00735 potentiometer position sensor for recirculation flap G143.
Https Encrypted Tbn0 Gstatic Com Images Q Tbn And9gcrwc8 9vpaaenvavbv81xoi3rohphbejvd2hx83xdv3 76ddk92 Usqp Cau
00735 potentiometer in positioning motor for air recirculation flap g143
00735 potentiometer in positioning motor for air recirculation flap g143
Diy Hvac Flap Motor Potentiometer Cleaning Audi Forum Audi Forums For The A4 S4 Tt A3 A6 And More